Title

Variations on the Degree of High Order Corneal Optical Aberrations in Patients Diagnosed with Corneal Ectasia with Intrastromal Rings Implanted

Resumen

Objetivo: identificar si existen variaciones significativas en el grado de aberraciones corneales de alto orden después del implante de los anillos intraestromales, en pacientes diagnosticados con ectasias corneales. Materiales y métodos: se realizó un estudio analítico y longitudinal de intervención en pacientes mayores de 18 años. Se valoró el estado refractivo; la agudeza visual medida con log mar; la queratometría topográfica; las aberraciones ópticas corneales coma, trifoid, esférica y el Root Mean Square High Order (rms Ho), mediante el topógrafo Keratron Scout, y la calidad visual por medio de la prueba de letras de Mars para la sensibilidad al contraste. Todo lo anterior en tres momentos antes de la intervención, primer y tercer mes postoperatorio. Resultados: en 39 ojos de 26 pacientes evaluados antes, al mes y al tercer mes después del implante se presentaron diferencias significativamente clínicas, aunque no estadísticas: a) se incrementó la agudeza visual sin corrección, b) hubo disminución del valor esférico y cilíndrico, c) aplanamiento en la K1 y K2, d) diferencias en cuanto al grado de aberraciones ópticas de alto orden corneales, después del procedimiento, e) una mejor calidad visual para estos pacientes y f) uso de lentes oftálmicos con mayor tolerancia. Conclusión: las aberraciones ópticas de la superficie anterior de la córnea no presentan una diferencia estadísticamente significativa antes y después del implante de segmentos intraestromales, aunque sí existen cambios a nivel clínico y en magnitud.

Palabras clave

ectasias, aberraciones ópticas corneales, rms de alto orden, anillos intraestromales, polinomios de Zernike, agudeza visual logmar, sensibilidad al contraste

Abstract

Objective: To identify whether there are significant variations in the degree of higher-order corneal aberrations after implantation of intrastromal rings in patients diagnosed with corneal ectasia. Materials and methods: An analytical and longitudinal study of intervention in patients over 18 years was carried out. The refractive state was evaluated, as well as the visual acuity measured by logmar; the topographic keratometry, the corneal optical aberrations coma, the trifoid, the spherical and the Root Mean Square High Order (rms Ho), by the Keratron Scout topograph, and the visual quality through Mars letters test for contrast sensitivity. All of this was done in three times before surgery, first and third post-op months. Results: In 39 eyes of 26 patients evaluated before, after one and three months after the implantation, clinical differences were significant, though not statistical: a) visual acuity was increased with no correction, b) there was a decrease in spherical and cylindrical values, c) flattening in K1 and K2, d) differences in the degree of high order optical aberrations of cornea after the procedure, e) a better visual quality for these patients and f) use of ophthalmic lenses with a greater tolerance. Conclusion: The optical aberrations of the anterior surface of the cornea do not have a statistically significant difference before or after the implantation of intrastromal segments, although there are changes at a clinical level and in magnitude.

Keywords

ectasia, corneal optical aberrations, high order root mean square, intrastromal rings, Zernike polynomials, log mar visual acuity, contrast sensitivity

Digital Object Identifier (DOI)

https://doi.org/10.19052/sv.93

Fecha de recepción

1 de febrero de 2012

Fecha de aceptación

8 de marzo de 2012

Fecha de publicación

January 2012

Licencia Creative Commons

Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.

Tipo de documento

Artículo de investigación

Editorial

Universidad de La Salle. Ediciones Unisalle

Compartir

COinS