•  
  •  
 

Title

Changes in the ocular surface and tear film during 30 days of daily use of hydrogel and silicone hydrogel soft contact lens

Resumen

Los cambios fisiológicos y morfológicos inducidos por los lentes de contacto (LC) se deben principalmente a hipoxia, trauma mecánico y toxicidad, relacionados con el tiempo de uso de LC. Objetivo: determinar los cambios en la superficie ocular y en la película lagrimal durante 30 días de uso diario de LC de hidrogel e hidrogel de silicona. Materiales y métodos: 20 sujetos, neófitos en el uso de LC firmaron el consentimiento informado y se adaptaron con lotrafilcon A y vasurfilcon A. Antes de la adaptación y en cada uno de los controles (4 y 8 horas, días 3, 7, 11, 15, 19, 23, 27 y 30) se evaluó hiperemia conjuntival, Schirmer I, TBUT, tinción corneal y confort. Se usaron la prueba de rangos de Wilcoxon (IC 95 %), el test de Mann-Whitney (IC 95 %) y la correlación de Spearman. Resultados: a partir de las 4 horas de uso de los dos lentes se evidenciaron alteraciones en todas las pruebas estudiadas. La mayor disminución (p < 0,05) en la calidad de la película lagrimal fue al día 3 del uso de lotrafilcon A y vasurfilcon A (4,5 y 5,5 s, respectivamente) y en la cantidad de película lagrimal fue al día 30 (12 min/5 min y 9 min/5 min, respectivamente). Durante los 30 días hubo un incremento gradual del porcentaje de pacientes con tinción corneal e hiperemia conjuntival. No hubo diferencias estadísticas (p > 0,05) ni clínicamente significativas entre los dos grupos de lentes. Conclusiones: los LC blandos de alto y bajo Dk/t durante 30 días de uso diario causan cambios significativos en la superficie ocular y en la película lagrimal, sin presentar diferencia entre los cambios generados por los dos tipos de lentes.

Palabras clave

lentes de contacto, película lagrimal, superficie ocular, confort

Abstract

Morphological and physiological changes induced by contact lens (CL) are mainly due to hypoxia, mechanical trauma and toxicity associated with time of use of CL. Objective: To determine changes in the ocular surface and tear film during 30 days of daily use of hydrogel and silicone hydrogel CL. Materials and Methods: 20 individuals, novices in the use of CL signed an informed consent and were adapted with Lotrafilcon A and Vasurfilcon A. Conjunctival hyperemia, Schirmer I, TBUT, corneal staining and comfort were assessed before adaptation and during each check-up (4 and 8 hours, day 3, 7, 11, 15, 19, 23, 27 and 30). The Wilcoxon rank test (IC 95 %), the Mann/Whitney test (IC 95 %) and the Spearman correlation were used. Results: Alterations were evident in all tests studied after 4 hours of use of the two lenses. The greatest decrease (p < 0.05) in the tear film quality was on day 3 of use of Lotrafilcon A and Vasurfilcon A (4.5 s and 5.5 s, respectively) and in the quantity of the tear film was on day 30 (12 min/5 min and 9 min/5 min, respectively). There was a gradual increase in the percentage of patients with corneal staining and with conjunctival hyperemia during the 30 days. There were no statistical differences (p > 0.05) or clinically significant differences between the two groups of lenses. Conclusions: Soft CL with high and low Dk/t during 30 days of daily use cause significant changes in the ocular surface and tear film, without showing any differences among the changes generated by the two types of lenses.

Keywords

contact lenses, tear film, ocular surface, comfort

Digital Object Identifier (DOI)

https://doi.org/10.19052/sv.1435

Fecha de recepción

24 de agosto de 2012

Fecha de aceptación

17 de septiembre de 2012

Fecha de publicación

January 2012

Licencia Creative Commons

Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.

Tipo de documento

Artículo de investigación

Editorial

Universidad de La Salle. Ediciones Unisalle

Compartir

COinS