•  
  •  
 

Title

Evaluation of Higher-Order Corneal and Ocular AberrationsUsing the Root Mean Square (RMS ) Index with Two Soft Aspheric Lensesin Patients with LowMyopic Astigmatism

Resumen

Objetivo determinar cuál lente de contacto blando asférico (Pure Vision o Definition AC) modificamás el valor Root Mean Square (RMS ) de alto orden en las aberraciones oculares y cornealesen pacientes con astigmatismo miópico bajo. Materiales y métodos se estudiaron cuarenta ojoscon astigmatismo miópico con la regla con esferas no mayores a -3,00 D y cilindros menores a-1,25 D, no usuarios de lentes de contacto a quienes se les realizaron aberrometrías con el aberrómetroCoas y con el topógrafo Keratron Scout en tres momentos: sin lente de contacto, conlente Pure Vision y con Definition AC. Resultados con ambos lentes se aumenta el RMS de altoorden ocular y corneal. El lente Pure Vision aumenta más el RMS de alto orden corneal (16%)que el Definition AC (12,9%), y este aumenta más el RMS de alto orden ocular (19%) que elPure Vision (8%). La aberración corneal que más se modificó fue la de coma, y la esférica paralas aberraciones oculares. Ambos lentes tuvieron un efecto significativo en la aberración esféricadisminuyéndola, tanto en las aberraciones oculares como en las corneales. Conclusiones aunque los dos lentes de contacto aumentan el RMS de alto orden, tanto el ocular como el corneal, enel presente estudio el lente que tuvo un mejor rendimiento óptico fue el Pure Vision, ya que fueel que menos aumentó el RMS ocular de alto orden.

Palabras clave

aberraciones oculares, aberraciones corneales, lentes de contacto, RMS

Abstract

Objective To determine which soft aspheric lens (Pure Vision or Definition AC) better modifiesthe higher-order RMS value in ocular and corneal aberrations in patients with low myopic astigmatism. Materials and Methodologies Forty eyes with myopic astigmatism were studied using alensometer with spheres no higher than -3.00 D and cylinders lower than -1.25 D, non contactlens users to whom aberrometries were performed with the COAS aberrometer and with topographerKeratron Scout at three different moments: without any contact lens, using Pure Visionand using Definition AC. Results Higher-order ocular and corneal RMS increased with bothlenses. Higher-order corneal RMS increases more with Pure Vision (16%) than with DefinitionAC (12.9%), while higher-order ocular RMS increases more with Definition AC (19%) than withPure Vision (8%). Coma aberrations were the corneal aberrations that changed the most; sphericalaberrations, on the other hand, were the ocular aberrations that experienced the most changes.Both lenses had a significant effect on the spherical aberration, diminishing it both in ocular andcorneal aberrations. Conclusions Even though both contact lenses increase the higher-orderocular and corneal RMS , Pure Vision was the lens that showed the best optical performance inthis study, as it is the one that increased higher-order ocular RMS the least.

Keywords

ocular aberrations, corneal aberrations, contact lenses, RMS

Fecha de recepción

10 de julio de 2011

Fecha de aceptación

8 de septiembre de 2011

Fecha de publicación

January 2011

Licencia Creative Commons

Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.

Tipo de documento

Artículo de investigación

Editorial

Universidad de La Salle. Ediciones Unisalle

Compartir

COinS